ElemeNtS

ElemeNtS is the most advanced, modular, analytical system
which detects Total Sulfur and/or Total Nitrogen

Hor_ElemeNtS_BID_749_Front

Simultaneous analysis of total sulfur and total nitrogen in one single run

The analyzer is equipped with a 10” touchscreen interface for direct queue control and diagnostics. The instrument has a modern design with an easily accessible front door for effortless maintenance. And the overall size of the instrument helps to reduce bench space.

Now in horizontal configuration, ElemeNtS has a boat inlet introduction ideal for solids and heavy liquids.

ElemeNtS is the most advanced, modular, analytical system which detects Total Sulfur and/or Total Nitrogen efficiently using Ultraviolet Fluorescence (UVF) and Chemiluminescence (CLD) in solid, liquid, gaseous materials, and LPG samples.
ElemeNtS_autosampler-small

Both configurations can be used with the high-capacity liquid auto-samplers:

749 Autosampler:
Vertical configuration —
a total of 324 x 2mL-vials can be stored on two tray holders.

Horizontal configuration — a total of 162 x 2mL-vials can be stored on one tray holder.

Available sizes: 10, 25, 50, and 100 µl.

Alternative sample introduction possibilities are:

  • Single Shot Autosampler: Cost-effective solution for injecting a single replicate sample by syringe on the vertical configurations. Available size: 25 µl
  • Manual injection: Manual sample introduction of both liquid and solids samples on the horizontal configurations
  • Accura Gas Injection: The ElemeNtS, in combination with PAC’s Accura, is an excellent solution for the introduction of gaseous and LPG samples

 

See Why our Customers Trust the ElemeNtS

 for Reliable and Accurate Analysis

 

blue-waves

Top Reasons to Choose ElemeNtS

High Performance for Wide Application Range and Quick Analysis

State-of-the-Art Technology Provides Excellent Precision and Long-Term Stability

Improved Lab Productivity Through Reduced User Intervention

Proven Compliancy for Multiple Industries

elements-brochure-cover

Get the Brochure

Learn more about the smallest simultaneous combustion analyzer on the market.

Application Notes

Title
Description
PDF

ASTM D4629

Trace Nitrogen in Liquid Petroleum Hydrocarbons by Syringe/Inlet Oxidative Combustion and Chemiluminescence Detection according to ASTM D4629.

View All Application Notes

ASTM D5453

Determination of Total Sulfur in Light Hydrocarbons, Spark Ignition Engine Fuel, Diesel Engine Fuel, and Engine oil by UVF according to ASTM D5453.

ASTM D6667

Determination of Total Volatile Sulfur in Gaseous Hydrocarbons and Liquefied Petroleum Gases by Ultraviolet Fluorescence according to ASTM D6667.

ASTM D7183

Determination of Total Sulfur in Aromatic Hydrocarbons and Related Chemicals by Ultraviolet Fluorescence according to ASTM D7183.

ASTM D7184

Ultra low Nitrogen in Aromatic Hydrocarbons by Oxidative Combustion and Reduced Pressure Chemiluminescence detection according to ASTM D7184.

EN 15486

Determination of Sulfur content of Ethanol as blending component for petrol according to EN 15486.

ISO 20846

Determination of Sulfur content in Automotive fuels using Ultraviolet Fluorescence method according to ISO 20846.

Nitrogen in Polymers

Determination of Nitrogen in Polymers by Boat-inlet Combustion and Chemiluminescence.

Sulfur in ECA Marine Fuels

Determination of Total Sulfur in ECA Marine Fuel according to ASTM D5453; EPA/MARPOL annex VI; D2622 correlation

Sulfur in biofuels from feedstock to end-product

Determination of Total Sulfur in Biofuels, from Feedstock to End-product according to ASTM D5453.

Sulfur in Polymers

Determination of Sulfur in Polymers by Boat-inlet Combustion and UV-fluorescence

Tier 3 Compliancy Elements

Determination of Total Sulfur in Gasoline by UVF according to ASTM D5453/TIER 3.

Total Analysis of Sulfur and Nitrogen in Biofuel

The Analysis of Total Sulfur and Nitrogen in Biofuel and Biofuel Feedstocks

Total Nitrogen in Water by Pyrolysis and Chemiluminescence Detection

Total Chemically Bound Nitrogen in Water by Pyrolysis and Chemiluminescence Detection according to ASTM D5176.

Determination of Nitrogen in Lubrication Oil on Horizontal Elements

Determination of Nitrogen in Lubrication Oils using Boat-Inlet Combustion and Chemiluminescence

Determination of Sulfur in Food

Determination of Sulfur in Food using Combustion UV-Fluorescence with the horizontal ElemeNtS

DIN 51444

Determination of bound Nitrogen in Petroleum products by Combustion and Chemiluminescence according to DIN 51444

Accura Multiloop Calibration

Total Sulfur and Nitrogen Calibration for Gaseous Hydrocarbons and LPG using the Multiloop feature of the Accura sampling device

Elements Nitrogen Interference Kit

Interference-free Determination of Total Sulfur by UV-Fluorescence in Fuels with High Levels of Nitrogen

Renewable Fuel Solutions_2x

Renewable Fuel Testing Solution

ElemeNtS detects Total Sulfur and/or Total Nitrogen efficiently using ultraviolet fluorescence (UVF) and chemiluminescence (CLD) in solid, liquid, gaseous materials and LPG samples.

nsure

Online Process Solutions

PAC also offers the NSure online analyzer to determine total sulfur and total nitrogen in a single analyzer while allowing you to control your process with continuous measurements.

Shape Waves Background

Get Started